The
AN900-A series are dual photoelectric detectors
designed
to provide reliable perimeter security both
indoors and outdoors. |
It
consists of separate transmitters and receivers.
The transmitter emits invisi ble infrared beams
with changing freque ncies to the receiver.
The frequencies change In a certain range to
protect beams from disturbance.
The changing frequencies feature can also help
cut power consumption to extend the detectors
life span.
Quick alignment system is built-in to speed
up accurate and reliable positioning. This detector
uses 2 pulsed infrared beams that are designed
to activate an alarm only when both 2 beams
are simul taneously blocked. |
 |
 |
|
|
| |
|
 |
|
|
| |
Design
Durability |
Highly
Durable and Heat-Resistant Housing Cover and
Chassis
The housing cover and chassis provide higher
durability against shocks, high temperatures,
and many other harsh environmental conditions.
|
Frost
and Dew Protection |
| An anti-frost
and convex visor design is incorporated to protect
the detector from effect of frost and dew. |
|
|
High
Grade Aspherical Lens |
| The
high grade Aspherical lens creates more sharply
defined and precise infrared beams compared
to ordinary fresnel lenses |
|
|
99.5%
Beam Blocking stability |
| Stable
operation is maintained with asmuch as 99.5%
of the beam's energyblocked by heavy rain,dust
storms,Snow or fog. |
|
|
Twin
Synchronized Pulsed Beams Designed for Greater
Stability |
| "And
Gate" dual beams require simultaneous interruption
of both beams to trigger an activation. No activation
is generated when a bird or falling leaves break
just one beam |
Adjustable
Beam Interruption Period |
| The Beam
Interruption Time (the amount of time a beam
must be broken for an alarm to occur) can be
adjusted to fit any application. For example,
when protecting a wall or fence, a longer interruption
time will catch intruders, but let jumping cats
pass through without setting off an alarm |
 |
|
Top |
 |
Quick
optical and voltage alignment to speed up positioning |
A
conveniently placed viewfinder allows for easyalignent
even in some of the most difficult mounting
situations. In the receiver there are two holes
indicating for voltage measuring.Fine the beam
and use a voltmeter to measure the voltage until
the suggested value appears. The rotating dial
and voltage measuring allows the installer to
finely adjust the beam easily horizontally (+180 /
+90 )
or vertically (+10 /
+ 5 ).
|
A.G.C.
(Automatic Gain Control) Circuit |
| The
A.G.C. Circuit continually monitors forgradual
changes in the signal's strength caused by changing
weather conditions. It adjusts the sensitivity
accordingly to maintain the proper signal level
for the current Environmental conditions |
 |
DIMENSIONS |
 |
|
 |
|
DIMENSIONS |
| MODEL |
AN900-A30 |
AN900-A60 |
AN900-A80 |
AN900-A100 |
| Detection
method |
Infrared
photoelectric |
| Range |
Outdoor |
30m |
60m |
80m |
100m |
| Indoor |
90m |
180m |
240m |
300m |
| Beam
characteristics |
Pulsed
infrared dual beams |
| Interruption
period |
50~700msec(selectable) |
| Power
input |
DC12~24V/AC11~18V |
| Current
consumption |
40mA
max |
55mA
max |
65mA
max |
65mA
max |
| Alarm
period |
2Sec(¡À1)nominal |
| Alarm
output |
Form
C relay (AC/DC30V 0.5A max) |
| Tamper
switch |
N.C.Opens
when cover is removed (receiver only) |
| Operating
temperature |
-25¡æ~+55¡æ |
| Environment
humidity |
95%
max |
| Alignment
angle |
¡À5¡ãvertical,¡À90¡ãhorizontal |
| Mounting |
Wall
or pole |
| Weight |
300g(Both
transmitter and receiver) |
| Appearance |
PC
Resin(Black) |
|
|
| Specifications
and design are subject to change without prior notice. |